A fluorometric method is described which provides sensitive measurements of extracted chlorophyll a free from the errors associated with conventional acidification techniques. Fluorometric optical configurations were optimized to produce maximum sensitivity to Chl a while maintaining desensitized responses from both Chl b and pheopigments. Under the most extreme Chl b :Chl a ratio likely to occur in nature (1 : 1 molar), the new method results in only a 10% overestimate of the true Chl a value, while estimates from older acidification methods are 2.5‐fold low. Under conditions of high pheopigment concentrations (pheo a: Chl a = 1 : 1 molar), the new method provides Chl a estimates that are equivalent to those determined from the acidification technique. The new simple method requires a single fluorescence determination and provides adequate sensitivity for small sample sizes (<200 ml) even in the most oligotrophic marine and freshwater environments.

Cite this paper

Welschmeyer, N. A. (1994). Fluorometric analysis of chlorophyll a in the presence of chlorophyll b and pheopigments. Limnology and Oceanography, 39(8), 1985–1992. https://doi.org/10.4319/lo.1994.39.8.1985

Read it with every claim anchored

Add this paper to a project, ask questions of it, and get answers that point to the exact passage.

Start free
  1. STUDIES OF MARINE PLANKTONIC DIATOMS: I. CYCLOTELLA NANA HUSTEDT, AND DETONULA CONFERVACEA (CLEVE) GRAN.1962
  2. Spreading Dead Zones and Consequences for Marine Ecosystems2008
  3. Primary Production of the Biosphere: Integrating Terrestrial and Oceanic Components1998
  4. Fluorescence Excitation−Emission Matrix Regional Integration to Quantify Spectra for Dissolved Organic Matter2003
  5. NONPOINT POLLUTION OF SURFACE WATERS WITH PHOSPHORUS AND NITROGEN1998

Metadata from OpenAlex (CC0). Citations are generated from the published record.